INTERVENTIONALRADIOLOGY
Interventional radiology (IR) is a medical specialty that performs minimally invasive treatments using radiologic imaging for procedure guidance. Interventional radiology treatments have become the primary method of care for a variety of conditions, offering less risk, less pain and less recovery time, compared to open surgery.
IR was founded in the early 1960s by Charles Dotter, MD, who invented angioplasty and the catheter-delivered stent, which were first used to treat peripheral arterial disease.
Systém periferního stentgrafu Plus jedinečně kombinuje mimořádnou radiální sílu spolu s pozoruhodnou flexibilitou.
The BeGraft Peripheral Plus Stent Graft System is indicated for intraluminal chronic placement in iliac and renal arteries for:
-
restoring and improving the patency
-
treating aneurysms, acute perforations, acute ruptures and fistulas
Reliable sealing properties through unique sandwich design. Smooth lesion access through high flexibility. Strong performance in complex lesions through increased radial force.
The one-layer peripheral stent graft system excels with a high radial force whilst maintaining extraordinary flexibility and a low profile. The cobalt-chrome stent platform is covered with a micro-porous ePTFE membrane.
The BeGraft Peripheral Stent Graft System is indicated for intraluminal chronic placement in iliac and renal arteries for:
-
restoring and improving the patency
-
treating aneurysms, acute perforations, acute ruptures and fistulas
Less trauma, faster procedures trough low profile (6FR compatibility up to 8mm diameter). Outstanding lesion access through exceptional flexibility. Predictable stent behaviour through low foreshortening & high radial force.
BeYond Venous Self-Expanding Stent System Thrombosis is known to be a wide spread disease. Venous stenting is proven to have a positive impact on the quality of life, especially of young and active people. The BeYond Venous Stent is designed to respect the natural venous anatomy to ensure the optimal balance between radial force, flexibility and deployment behaviour.
Optimized radial force developed to restore reliable blood flow in the affected vessel
Effortless flexibility enhanced performance and kink resistance to adapt to the venous anatomy
Accurate deployment ensuring predictable landing zone and minimal foreshortening
One-layer peripheral stent graft system for large diameter vessels.
The stent platform made of cobalt-chrome is covered with
a micro-porous ePTFE membrane and is characterized with
a high radial force at predictable foreshortening.
The BeGraft Aortic Stent Graft System is indicated for:
-
the implantation in the native and / or recurrent coarctation of the aorta (CoA) on adolescent or adult patients
-
restoring and improving the patency of the iliac arteries
High conformability and stability through stent design & CoCr material with outstanding flexibility and radial force. Predictable stent behavior through predictable foreshortening. Optimized lesion care through wide range of diameters ( 12 – 24 mm ) and lengths ( 19 - 59 mm ).
The peripheral stent system excels with a high radial force whilst maintaining extraordinary flexibility and a low profile.
The BeSmooth Peripheral Stent System is indicated for the treatment of de novo or restenotic artherosclerotic lesions in protected peripheral arteries.
Less trauma, faster procedures through low profile (6 FR compatibility up to all sizes). Outstanding lesion access through exceptional flexibility. High conformability & stability through stent design & CoCr material with high radial force.
The peripheral stent system excels with a high radial force whilst maintaining extraordinary flexibility and a low profile.
The BeSmooth Peripheral Stent System is indicated for the treatment of de novo or restenotic artherosclerotic lesions in protected peripheral arteries.
Less trauma, faster procedures through low profile (6 FR compatibility up to all sizes). Outstanding lesion access through exceptional flexibility. High conformability & stability through stent design & CoCr material with high radial force.
BeBack crossing catheter
BeBack Crossing Catheter is a low-profile, crossing and targeted re-entry support catheter with a nitinol needle with adjustable length and 360° rotation.
Available in 2.9F and 4.0F for retrograde, antegrade and crossover access. With BeBack crossing catheter, multiple options such as antegrade, retrograde and crossover can be used for intraluminal and subintimal access to stenotic or occluded lesions.
This makes the BeBack crossing catheter compatible with 0.014" and 0.018" guidewire an effective solution for peripheral recanalization.